Address 11160 grace avenue fountain valley ca 92708.
Water heater single wall vent.
Apollopex corrugated the 3 4 in.
Exhaust gases are vented outdoors through a separate vent duct or through a separate chamber of the same pipe this requires a double wall vent duct.
Instead both systems typically expel exhaust through a pipe that runs outside through an exterior wall.
6 minimum clearance from single wall vent pipe or flue vent connector to any combustible material.
Direct vent water heaters.
Apollopex corrugated stainless steel water heater connector was designed for the fast and simple installation of hot and cold water lines to water heaters using pex connections.
For gas fired water heater vents.
An exception is made for non combustible walls such as solid masonry or concrete.
Single wall vent pipes cannot pass through a ceiling floor firewall or wall.
Single wall natural draft gas water heater vent pipe cannot be used in unheated areas like attic or garage even if only partially penetrating that space because such vent pipe installation will cause excessive condensation on vent pipe walls and compromise proper drafting double wall pipe b vent type is required.